Lecturer

Phone: +86-15972007990

Email: yujinghua323@126.com

Academic Areas: Building Services Engineering, Heating Ventilation and Air-Conditioning, Building Technology Science

Research Interests: Building energy conservation and the application of renewable energy, Indoor thermal comfort, Energy saving operation and optimal control of air conditioning system

I majored in Building services engineering; I got the bachelor’s degree in 2004 and the doctor’s degree in 2009 in Hunan University, China. Then I worked in School of environmental science and engineering, Huazhong University of Science and Technology. I am engaging in the research on building energy conservation and indoor thermal comfort, and successively managed one project supported by National Natural Science Foundation of China, one project supported by Doctoral Funds for Higher Education of China; three projects supported by the Fundamental Research Funds for the Central Universities, one project cooperated with enterprise. Also I have participated some national and provincial projects and some projects cooperated with enterprise. More than forty academic papers have been published until now and more than thirty papers have been cited by SCI, EI or ISTP. In 2008As Guest Editors I published the international special issue entitled <Energy conservation and the built environment>.

Academic Degrees

2000.9-2004.6 Dept. of Building Services Engineering, College of Civil Engineering, Hunan University, bachelors degree.

2004.9-2006.6 Dept. of Heating Ventilation and Air-Conditioning, College of Civil Engineering, Hunan University, masters degree.

2006.9-2009.9 Dept. of Heating Ventilation and Air-Conditioning, College of Civil Engineering, Hunan University, doctor's degree.

Professional Experience

2010. 3-now Dept. of Building Services Engineering, School of Environmental Science and Engineering, Huazhong University of Science and Technology, associate professor

Selected Publications

International journals

[1] Jinghua Yu, Jian Yang, Chao Xiong, Study of dynamic thermal performance of hollow block ventilated wall, Renewable Energy 84 (2015) 145-151

[2] Jinghua Yu, Liwei Tian, Xinhua Xua, Jinbo Wang, Evaluation on energy and thermal performance for office building envelope in different climate zones of China. Energy and Buildings 86 (2015) 626–639

[3] Jinghua Yu, Yu Liu, Chao Xiong, Jun chao Huang. Study on Daylighting and Energy Conservation Design of Transparent Envelope for office building in Hot Summer and Cold Winter Zone .Procedia Engineering 121 ( 2015 )  1642 – 1649

[4] Jian Yang, Jinghua Yu, Xiong Chao .Heat Transfer Analysis of Hollow Block Ventilated Wall Based on CFD Modeling. Procedia Engineering 121 ( 2015 )  1312 – 1317

[5] Xiong Chao, Jinghua Yu, Jian Yang. Study of the Simplified Dynamic Thermal Network Model for the Hollow Block Ventilated Wall. Procedia Engineering  121  ( 2015 )  1304 – 1311  

[6] Xinhua Xu, Jinghua Yu, Shengwei Wang, Jinbo Wang,Research and application of active hollow core slabs in building systems for utilizing low energy sources, Applied Energy 116 (2014) 424–435

[7] Jinghua Yu, Liwei Tian, Weiqian Zhuang, Jian Yang. Prediction of the pollutant diffusion discharged from wind tower of the city traffic tunnel. Tunnelling and Underground Space Technology 42 (2014) 112–121

[8] Jinghua Yu, Liwei Tian, Changzhi Yang, Xinhua Xu, Jinbo Wang. Sensitivity analysis of energy performance for high-rise residential envelope in hot summer and cold winter zone of China, Energy and Buildings 64 (2013) 264–274

[9] Jinghua Yu, Liwei Tian, Changzhi Yang, Xinhua Xu, Jinbo Wang. Optimum insulation thickness of residential roof with respect to solar-air degree-hours in hot summer and cold winter zone of china ,Energy and Buildings, 2011,43(9) :2304-2313(SCI/EI).

[10] Jinghua Yu, Changzhi Yang, Liwei Tian and Dan Liao.A study on optimum insulation thicknesses of external walls in hot summer and cold winter zone of China.Applied energy, 2009,86(11):2520-2529 (SCI/EI).

[11] Jinghua Yu, Changzhi Yang, Liwei Tian and Dan Liao.Evaluation on energy and thermal performance for residential envelopes in hot summer and cold winter zone of China.Applied Energy, 2009,86(10):1970-1985 (SCI/EI).

[12] Jinghua Yu, Changzhi Yang and Liwei Tian.Low-energy envelope design of residential building in hot summer and cold winter zone in China.Energy and Buildings, 2008, 40 (8) 1536-1546 (SCI/EI).

[13] Jinghua Yu, Changzhi Yang, Liwei Tian and Dan Liao.Methodology for calculating the energy consumption of air-conditioner in residential building of China.International Journal of Energy Technology and Policy, 2008, 6(5/6):458-473 (EI).

[14]Chong Zhang, Jinbo Wang, Xinhua Xu, Fuxi Zou, Jinghua Yu. Modeling and thermal performance evaluation of a switchable triple glazing exhaust air window.Applied Thermal Engineering, Volume 92, 5 January 2016, Pages 8-17

[15] Liwei Tian, Guoqiang Zhang, Jinghua Yu, Quan Zhang and Jin Zhou.Impact of surface roughness on particle penetration through building envelope leakage.International Journal of Energy Technology and Policy, 2008, 6(Nos.5/6):534-542(EI).

[16] Liwei Tian, Guoqiang Zhang, Yaolin Lin, Jinghua Yu, et.al..Mathematical model of particle penetration through smooth/rough building envelop leakages, Building and Environment, 2009,44(6):1144-1149(SCI/EI).

International conferences

[1] Jinghua Yu, Liwei Tian, Xinhua Xu, Jian Yang. Research process on thermal modeling of hollow Block ventilated wall. APEC Conference on Low-carbon Towns and Physical Energy Storage May 25-26, 2013, Changsha, China, 551-555

[2] Jinghua Yu, Liwei Tian,Changzhi Yang, Xinhua Xu, JinboWang. Analysis of energy efficiency design of residential envelopes by using EETP index. In:The 7th International Symposium on Heating Ventilating and Air  Conditioning.Shanghai, November, 2011, 108-116(EI).

[3] Jinghua Yu, Liwei Tian, Changzhi Yang, Xinhua Xu, JinboWang. Economic performance of energy conservation measures for residential envelopes in hot summer and cold winter zone of china. In:The 7th International Symposium on Heating Ventilating and Air Conditioning.Shanghai, November, 2011, 117-124(EI) .

[4] Jinghua Yu, Xinhua Xu, Liwei Tian. Effect of envelope design on energy consumption respect to EETP index. Proceedings of International Conference on Energy and Environment Technology, Changsha, Feb, 2011:1140-1143 (EI).

[5] Jinghua Yu, Changzhi Yang, Liwei Tian, Dan Chen. Study of the optimum insulation thickness of opaque envelope using solar-air degree-days.In:The 6th International Symposium on Heating Ventilating and Air Conditioning.Nanjing, November, 2009,153-159 (EI收录).

[6] Jinghua Yu, Changzhi Yang, Liwei Tian, Dan Chen. A case study on optimum insulation thickness of a residential roof in hot summer and cold winter zone of china.Proceedings of the 6th International Symposium on Heating Ventilating and Air Conditioning.Nanjing, November, 2009,160-165 ( EI)

[7] Jinghua Yu, Changzhi Yang, Dan Liao, Liwei Tian.Systemic evaluation of envelop thermal performance of residential buildings.Proceedings of the First International Conference on Building Energy and Environment.Dalian, July, 2008, 199-207 (ISTP).

[8] Jinghua Yu, Changzhi Yang, Liwei Tian, Dan Liao.Energy performance of window system in residential buildings.Proceedings of the First International Conference on Building Energy and Environment.Dalian, July, 2008, 208-214 (ISTP).

[9] Jinghua Yu, Changzhi Yang, Junwen Hu, Liwei Tian.Effects of envelope energy saving strategies on energy consumption in residential building. Proceedings of the 5th International Symposium on Heating Ventilating and Air Conditioning.Beijing, September, 2007, 849-857 (ISTP).

[10]Jinghua Yu, Changzhi Yang, Liwei Tian, Junwen Hu.Effects of envelope energy saving strategies on different rooms in residential building. Proceedings of the 5th International Symposium on Heating Ventilating and Air Conditioning.Beijing, September, 2007, 871-878 (ISTP).

[11]Jinghua Yu,Changzhi Yang,Rui Guo et al.The influence of operation modes, room temperature set point and curtain styles on energy consumption of room air conditioner.Proceedings of the 6th International Conference for Enhanced Building Operations.Shenzhen, November, 2006,Vol.V-4-4

[13]Zhu Qiuyuan, Xu Xinhua*, Yu Jinghua. Development of a dynamic simplified thermal model of active pipe-embedded building envelope. ASim 2012 IBPSA Asia Conference, Shanghai, Nov.25-27, 2012.

[14]Zhu Qiuyuan, Xu Xinhua, Yu Jinghua. Study of Dynamic Thermal Performance of Active Pipeembedded Building Envelopes Based on Frequency- Domain Finite Difference Method. ASim 2012 IBPSA Asia Conference, Shanghai, Nov.25-27, 2012.

[15]Dan Chen, Changzhi Yang, Jinghua Yu.Evaporative cooling techniques for handling outdoor air. Proceedings of the 6th International Symposium on Heating Ventilating and Air Conditioning.Nanjing, November, 2009: 1669-1676(EI).

[16]Junwen Hu, Changzhi Yang, Jinghua Yu.The energy saving effect analysis of the different exterior envelope construction energy saving measures in Changsha.Proceedings of the 5th International Symposium on Heating, Ventilation and Air Conditioning.Beijing, September, 2007, 891-896 (ISTP).

[17]Junwen Hu, Changzhi Yang, Jinghua Yu.Building energy analysis and simulation of Changsha area.Proceedings of the 10th International Building Performance Simulation Association Conference and Exhibition.Beijing, September, 2007, 1871-1876 (ISTP).

National journals

[1] YU Jing-hua, YANG Jian, XU Xinhua,TIAN Liwei.study on energy efficiency of hollow block ventilation wall,building science,2016,32(8):47-51.

[2] YU Jing-hua, YANG Jian, TIAN Liwei, XU Xinhua, Junchao Huang, Study of frequency domain based dynamic thermal model of hollow block ventilated wall. Building Energy and Environment, accepted.

[3] XIONG chao, YU Jing-hua, LIU Yu,HUANG Jun-chao,Simplified two-dimensional heat transfer model for the hollow block ventilated wall. Building Energy Efficiency,2016,44(2):43-47

[4] HUANG Jun-chao, YU Jinghua, TIAN Liwei, air distribution analysis for a certain sewage treatment plant, Refrigeration & Air Conditioning,2017(4), accepted.

[5] YU Jing-hua, Tian Liwei, Xu Xinhua, Yang Jian. Research process of thermal modeling of hollow block ventilated wall. Building Energy and Environment, 2014, 33(4):40-43

[6] YU Jing-hua, TIAN Li-wei, YANG Chang-zhi. Research on the optimum insulation thickness of   residential roof in hot summer and cold winter zone.Journal of Central South University (Science and Technology),2012,43(4)1545-1550 (EI).

[7] YU Jing-hua, TIAN Li-wei, YANG Chang-zhi. Sensitivity Analysis of Energy Consumption for Residential Envelope in Hot Summer and Cold Winter Zone.Building Energy&Environment,2012,21(1)41-45.

[8] YU Jing-hua, XU Xin-hua, TIAN Li-wei.Research on evaluation of energy and thermal performance for residential buildings based on EETP index, Journal of Huazhong University of Science and Technology 2011, 39(3) :124-127 (EI).

[9] YU Jing-hua , YANG Chang-zhi , TIAN Li-wei ,et.al.Research on the Optimum Insulation Thickness of the External Wall for Residential Buildings in Changsha Region, Journal of Hunan University(Natural Sciences), 2009, 36(9):16-20 (EI).

[10] YU Jing-hua , YANG Chang-zhi , TIAN Li-wei ,et.al.Systematic Evaluation of the Thermal Performance of Building Envelopes in Hot Summer and Cold Winter Zone, Journal of Hunan University(Natural Sciences), 2008, 35(10):15-19(EI).

[11] TIAN Li-wei, ZHANG Guo-qiang, YU Jing-hua. Mathematical Simulation of Particle Penetration through Smooth and Rough Building Envelop Leakage. Journal of Hunan University(Natural Sciences), 2008, 35(10):10-15(EI).

[12] Liao Dan, Yang Changzhi, Yu Jinghua.Optimization design on the temperature and temperature difference of cooling water in central air conditioning system.Proceedings of China railway Annual Seminar of HVAC&R, Suzhou, October, 2008, 50-54

[13] Guo Rui,Yang Changzhi,Yu Jinghua et.al.Analysis and Alteration to the Air-conditioning System Performance of the Exhibiting Hall of the Female Corpse of Han Dynasty in the Museum of Hunan Province.Refrigeration and air conditioning (Sichuan), 2007,(2):66-71.

 

Project

2016.09-2017.12 Study on energy saving technology of heat recovery gathered in large space at the top of the railway station, supported by China Railway Siyuan Survey and Design Group Limited Company, project manager.

2015.1-2016.12 the study on the thermal performance of hollow block ventilated wall, the Fundamental Research Funds for the Central Universities (No. 2015QN119), project manager.

2013.01-2015.12  Frequency domain based dynamic thermal model and experimental study of hollow block ventilated wall,the National Natural Science Foundation of China (Grant No. 51208221), project manager.

2013.1-2014.12 study on the day lighting and energy conservation design for Transparent envelope of office building in hot summer and cold winter zone,the Fundamental Research Funds for the Central Universities (2013QN069), project manager.

2012.01-2014.12 evaluation system of optimization design for office envelope, Doctoral Funds for Higher Education of China (Grant No. 20110142120084), project manager.

2011.06-2012.12 Analysis on optimization of insulation thickness for opaque building envelope, the Fundamental Research Funds for the Central Universities (NO. 2011QN123), project manager.

2012.01-2015.12 Dynamic thermal model and experimental study of Pipe-embedded Building Envelopes,the National Natural Science Foundation of China (51178201), key member.

2010.5-2010.11 Research on floor radiation heating and cooling system, supported by China Railway Siyuan Survey and Design Group Limited Company, key member.

2010.1-2010.6  Research on development model of building energy conservation in Wuhan city of hot summer and cold winter zone based on low-carbon economy, supported by United Nations Development Program, key member

Login and edit information